Intellisite’s unique Pump Off Controller (POC) data display enables the operator to manage and control single units to entire fields of Rod Pump Controllers. IntellisiteSM offers an industry leading web-based remote monitoring service that collects critical pumping unit data and converts it into information to help you efficiently manage and optimize your well sites. The POC Monitoring Service delivers field records of over 122 registers including surface and downhole cards on a daily basis.
•Track total daily run times and create detailed graphs for trending analysis.
•View shutdown cards over current surface and downhole cards.
•Set customized electronic alarm notifications of fault codes and threshold violations.
•Manage Rod Pump Units by exception and dispatch crews to the site with accurate information.
•Develop well treatments based on actual pump status using web generated load report graphs instead of calendar dates.
•Track peak polish and minimum polish rod loads; track events such as last start and stop, malfunction setpoint violations and resets, and AC power off.
•View run time hours against inferred production, polish rod horse power, peak and minimum rod loads. •Download and upload common controller settings remotely.
•Compare POC data against other lease assets, tanks, EFM and compressors.
•Create detailed operational reports and annotations direct from the web.
•Monitor and change control settings and fault thresholds via the internet.
IntellisiteSM offers four different service options that meet the specific needs of your site:
1. Communication and Services – If you need communication services, they include the following:
◦Translator Service
◦Web Display Service
◦Data Center Service
◦Client Support Service
2. Integration to SCADA Systems – Intellisite collects monitoring data from remote or out-of-network sites, transmits it to the Implicit Data Center, and then FTP’s the data to the client’s SCADA system.
3. Web Display – If you are collecting monitoring data, but need a powerful web-based reporting platform to display the information to all key decision makers in your organization, the Web Display option will meet this need.
4. Alarms Only – If you are only worried about catastrophic equipment failure and loss of production, a very inexpensive “Alarms Only” service will do. You can set the thresholds that trigger the alarms and define the notification path to your key personnel on an escalating basis, helping them manage trouble spots.
The Right Smart™ 1200 solution integrates the unique technologies of IntellisiteSM with your existing pumping units to deliver comprehensive and accurate measurement information through our powerful, web-based reporting platform. Right Smart™ collects key production data from your field equipment, builds a history, and then encodes and compresses it for efficient transfer via the best path: radio, telephone or satellite telemetry. The production data is transported in high security to the world-class Implicit™ Monitoring Solutions Data Center, where it is converted into decision-critical information that is delivered by our web-based reporting platform. The Right Smart™ kit is compactly designed and uses either a RS232 input port or a RS485 input port if required.
| Analog Inputs | (4) 0-5d or 1-5 Vdc |
| Discrete/ Pulse Input | (2) Dry Contact Closures |
| Discrete Output | (1) Open Collector, 15 Vdc @ 100 ma Max |
| Protection | Transient protection is provided in-circuit |
| Communications | Iridium Satellite |
| Optional Battery | 12Vdc, 15 AH |
| Optional Solar Panel | 10 watts to 20 watts |
| Local Readout | Optional LCD 4 x 20 characters; temperature compensated |
| Dimensions | 5.5" L x 2.5" H x 1.75" W (14cm L x 6.4cm L x 4.5cm H) |
| Operating Temperature | -40° to + 140° F not including LCD readout |
| Operating Humidity | 0 - 95% non-condensing |
| Meter Interfaces | Total Flow 6413, XF6413, and uFlow 6213 using modbus protocol Fisher FlowBoss 103 and 503 using ROC protocol NuFlo 1140 and 1150 using modbus protocol Eagle Research using modbus protocol |
| Alarms | Low DP, high DP, low AP, high DP, low flow rate, high flow rate, back flow, low flowing temperature, high flowing temperature, low battery voltage, high battery voltage, contact closures for compressors |